Where to mount each sensor: placement guide for presence, air, weather, leak and vibration sensors

Render of our free 3D-printable housing for the mmWave presence kit

Placement makes more difference to a home sensor than its spec sheet does. Here's where to put each type, and how our free housings mount.

Presence radar (mmWave)

  • Mount about 1.5–2 m high, facing the area you want covered. The Seeed 24 GHz radar for XIAO is rated for about 0.75–6 m and ±60°.
  • Keep it away from moving things: fans, curtains, plants in a draught, radiators and pets' favourite spots all show up as motion. Point it away from windows and thin walls, because radar passes through them.
  • Mount it on something solid. A wobbly bracket reads as a person.
  • Our Presence Lite and C4001 housings have keyhole ears for two screws and a flat radar window. Don't paint over the window.

PIR motion

  • PIR sensors work best when people walk across their view, not straight towards them. A corner at 2–2.5 m that looks across the room works well.
  • Keep them away from heaters, air vents and direct sun, which cause false triggers.
  • A PIR won't notice someone sitting still. Use radar for that.

Time-of-flight doorway and distance sensors

  • Mount above or beside the doorway so the beam crosses the path people walk.
  • Dark, shiny or angled surfaces return less light. Test at the real distance.
  • Keep the aperture clean and uncovered.

CO₂, VOC and particle sensors

  • Place them at breathing height (roughly 1–1.5 m) in the room you care about, away from windows, doors, cookers and anyone's direct breath.
  • Keep them out of direct sun and off radiators: heat skews the readings.
  • Particle sensors need free airflow at their inlet and outlet, so don't push the vent wall against furniture.
  • These readings are estimates for comparison and trends. They don't replace certified CO, smoke or gas alarms.

Weather and outdoor sensors

  • For air temperature, the WMO recommends measuring 1.25–2 m above the ground, in shade, with good ventilation. A printed box in the sun reads far too hot, so use a radiation shield or a shaded north-facing wall (south-facing in the southern hemisphere).
  • Mount boxes with cable entries facing down so water runs off. Print in ASA or PETG. A printed box isn't waterproof and we don't give it an IP rating.
  • Put rain gauges level and clear of overhanging roofs and trees.

Leak and flood sensors

  • Put leak sensors at the lowest point where water would collect first: under sinks, behind washing machines and dishwashers, next to water heaters and sump pits.
  • Our leak pucks hold the sensor board upright with its traces just touching the floor. Keep the controller box higher up the wall, out of the water.

Vibration (machines) and earthquakes

  • Bolt vibration sensors rigidly to the machine, close to the bearing or motor you're watching, and in the same orientation every time so readings are comparable. A screw mount transmits more high-frequency vibration than a magnet, and a magnet more than tape.
  • The Omron D7S seismic sensor should be fixed to the building structure (a solid wall or floor, not a shelf), and Omron specifies an installation angle within ±5°. Our Quake Sentinel housing has screw tabs for this.

Soil, water and energy

  • Insert soil probes up to the marked line, in the root zone, away from the pot edge. Keep the electronics box above the splash zone.
  • pH, TDS and temperature probes: mount the box above the reservoir with drip loops on the cables.
  • Energy clamps go around a single insulated conductor. Don't open a consumer unit or electrical panel unless you're qualified. Our housing holds only the low-voltage sensor board.

Get the matching housing for each kit on the 3D-printed housings page.

Note: This guide and our housing files are free recommendations for educational and informational purposes only. They come as-is, with no warranty of fit, safety or suitability, and you print, assemble, install and use them at your own risk, so check your printer, materials, wiring, heat and local codes yourself. Printed enclosures aren't certified for fire, electrical, outdoor, medical or life-safety use, and our sensor kits aren't safety devices or a substitute for certified smoke, CO or gas alarms. To the extent permitted by law, The Sensor Shop / American Data Analytics LLC isn't liable for damage, injury or loss from their use, and nothing here affects your statutory rights. Full DIY disclaimer.